返回

EI 防火阀

16 个型号 · EI 30 至 EI 180,按 ISO 10294-1 / ISO 21925-1 耐火测试

易熔片扭簧隔热防火阀,可组合
EI 120 FD · 易熔片
S-FSD-L210-0175.24
易熔片扭簧隔热防火阀,可组合

Symmetrical single-blade damper, 61.5 mm casing and blade, closed by torsion spring when the 70–74 °C fusible link releases; combinable for large ducts

W 200–2364 × H 200–1764 mm · 0175-2024/TNCL

易熔片扭簧隔热防火阀
EI 120 FD · 易熔片
S-FSD-L210-0723.23
易熔片扭簧隔热防火阀

Symmetrical single-blade damper, 61.5 mm casing and blade, closed by torsion spring when the 70–74 °C fusible link releases; combinable for large ducts

W 150–1200 × H 150–800 mm · 0723-2023/TNCL

温度熔断器・扭簧隔热防火阀
EI 120 FD · 易熔片
S-FSS-L210
温度熔断器・扭簧隔热防火阀

Symmetrical single-blade damper installed in a wall opening between two fire compartments; closed by a torsion spring when the 72 °C fusible link melts, no power supply needed

W 150–500 × H 150–500 mm · 0289-2024/TNCL

隔热单叶防火阀,Hoocon 执行器
EI 180 MFD · 执行器
S-MFD-FS-L400
隔热单叶防火阀,Hoocon 执行器

隔热单叶阀,阀体 400 mm,Hoocon 5 Nm 弹簧复位执行器;按 EN 1366-2 / ISO 21925-1 达到 EI 180

W 150–600 × H 150–600 mm · EN 1366-2 · ISO 21925-1 fire test, Guangzhou (CN), 2026 — EI 180; report shown to customers directly

配 KLB 执行器的隔热多叶防火阀
EI 180 MFD · 执行器
S-MFSD-M2/K
配 KLB 执行器的隔热多叶防火阀

Symmetrical multi-blade damper installed in the wall between two fire compartments, closing by spring return on power loss or fire alarm

W 150–1500 × H 150–800 mm · 0933-2026/TNCL-TT1

配Belimo执行器的隔热防火阀
EI 180 MFD · 执行器
S-MFSD-S1/B
配Belimo执行器的隔热防火阀

Symmetrical single-blade damper installed in the wall between two fire compartments, closing by spring return on power loss or fire alarm

W 150–1500 × H 150–800 mm · 0884-2026/TNCL-TT1

配Belimo执行器的隔热走廊防火阀
EI 120 MFD · 执行器
S-MFSD-L210
配Belimo执行器的隔热走廊防火阀

Symmetrical single-blade damper mounted on the face of a fire wall (fire side or non-fire side), closing by spring return on power loss or fire alarm

W 150–1200 × H 150–800 mm · 0204-2024/TNCL

配 Belimo 执行器的扩展组合式防火阀
EI 120 MFD · 执行器
S-MFSD-L210-C
配 Belimo 执行器的扩展组合式防火阀

Assembly of single-blade S-MFSD-L210 modules (each ≤ 1200 × 800) with 174 mm mullions, mounted on the wall between two fire compartments; each module closes by spring return on power loss or fire alarm

W 500–2500 × H 500–1700 mm · 0280-2024/TNCL

Belimo 执行器隔热防火阀 L600
EI 120 MFD · 执行器
S-MFSD-L600
Belimo 执行器隔热防火阀 L600

One damper, one 58 mm insulated blade, 600 mm casing, installed in the wall between two fire compartments. Fail-safe closing on power loss, status via auxiliary switches.

W 150–1200 × H 150–800 mm · 064.22.KC.NCPCC

隔热组合式防火阀 L600,1200 × 800 模块
EI 120 MFD · 执行器
S-MFSD-L600-C
隔热组合式防火阀 L600,1200 × 800 模块

Four 1200 × 800 modules joined 2 × 2 with 80 mm joints, each module with its own blade and actuator. For large single openings up to 2480 × 1680 mm.

W 1280–2480 × H 880–1680 mm · 066.22.KC.NCPCC

隔热防火阀 L600,双阀叶,一台 Belimo 执行器
EI 120 MFD · 执行器
S-MFSD-L600-D
隔热防火阀 L600,双阀叶,一台 Belimo 执行器

Two modules side by side in one casing, 100 mm mullion, two 58 mm blades driven by one actuator. For openings up to 2000 × 1000 mm.

W 1250–2000 × H 150–1000 mm · 332.22.KC.NCPCC

多叶防火阀 EI120
EI 120 MFD · 执行器
S-MFSD-MB
多叶防火阀 EI120

Parallel multi-blade damper installed in the wall between two fire compartments, closing by spring return on power loss or fire alarm

W 150–800 × H 150–1200 mm · 0838-2025/TNCL-TT1

配Belimo执行器的隔热防火阀
EI 60 MFD · 执行器
S-MFSD-WB
配Belimo执行器的隔热防火阀

Symmetrical damper, one blade per compartment (two compartments for W > 1200 mm), installed in the wall between two fire compartments, closing by spring return on power loss or fire alarm

W 150–1500 × H 150–600 mm · 0839-2025/TNCL-TT1

配 KLB 执行器的隔热防火阀
EI 60 MFD · 执行器
S-MFSD-WF
配 KLB 执行器的隔热防火阀

Two symmetrical blades in two sections (W > 1200 mm), installed in the wall between fire compartments, closing by spring return on power loss

W 150–1500 × H 150–600 mm · 0723-2025/TNCL-TT1

多叶隔热补风防火阀
EI 60 MFD · 执行器
SAFD-H-L210
多叶隔热补风防火阀

Parallel multi-blade damper installed in a wall opening between two fire compartments, supplying make-up air for smoke extraction; 2–10 V control, spring-return closing on power loss

W 150–1200 × H 150–800 mm · 0230-2024/TNCL-TT2

竖向多叶隔热补风防火阀
EI 30 MFD · 执行器
SAFD-L210
竖向多叶隔热补风防火阀

Vertical multi-blade damper installed in a wall opening between two fire compartments, supplying make-up air for smoke extraction; spring-return closing on power loss

W 150–800 × H 150–1200 mm · 0127-2024/TNCL-TT2

技术规格建议

本产品线的规格范本条款,可供顾问直接用于招标文件:查看、复制或打印。中立版不含品牌;Starduct 版另附参考产品及测试报告编号。

并配合通用章节: P15 – 所有产品通用要求