EI 防火ダンパー
16 モデル · EI 30〜EI 180、ISO 10294-1 / ISO 21925-1 耐火試験
Assembly of single-blade S-MFSD-L210 modules (each ≤ 1200 × 800) with 174 mm mullions, mounted on the wall between two fire compartments; each module closes by spring return on power loss or fire alarm
W 500–2500 × H 500–1700 mm · 0280-2024/TNCL
One damper, one 58 mm insulated blade, 600 mm casing, installed in the wall between two fire compartments. Fail-safe closing on power loss, status via auxiliary switches.
W 150–1200 × H 150–800 mm · 064.22.KC.NCPCC
Symmetrical damper, one blade per compartment (two compartments for W > 1200 mm), installed in the wall between two fire compartments, closing by spring return on power loss or fire alarm
W 150–1500 × H 150–600 mm · 0839-2025/TNCL-TT1
Parallel multi-blade damper installed in a wall opening between two fire compartments, supplying make-up air for smoke extraction; 2–10 V control, spring-return closing on power loss
W 150–1200 × H 150–800 mm · 0230-2024/TNCL-TT2
仕様書の提案
この製品ラインの標準仕様条項で、コンサルタントが入札図書にそのまま使えます:閲覧・コピー・印刷。中立版はブランド名なし、Starduct 記載版は試験報告書番号付きの参照製品ブロックを追加します。
- P4 – 防火ダンパー 規格:ISO 21925-1:2018 · TCVN 9311-1:2012 · EN 1366-2 / EN 15650 · QCVN 06:2023/BXD 中立版 →Starduct 記載版 →
共通項目とあわせて: P15 – 全製品共通の要求事項