Brand submittal tool — how to use · 4:16
Step by step: an A4 submittal for the client, design and supervision consultants to approve the Starduct brand — fill in the project, pick product groups, read each section, print or save as PDF. Project names in the video are samples.
Brand submittal
Enter the project details and pick the Starduct product groups → an A4 brand-approval submittal to print or save as PDF for the client, design consultant, supervision consultant and main contractor. Data is processed only in your browser.
Project and submittal details
Product groups to submit
Pick one or more groups. Models and data tiers come from the product pages.
The technical submittal per model (tag schedule, performance, drawings, DoP) is printed from each line's quick selector.
- Ref. / PO no.
- —
- Date
- —
- Revision
- —
1. Project information
| Project name | — |
|---|---|
| Location | — |
| Client / owner | — |
| Design consultant | — |
| Main contractor | — |
| Supervision consultant | — |
| MEP contractor | — |
| Prepared by | — |
2. Products submitted
| No. | Product group / models | Standards | Main construction | Basis of performance data | Documents provided |
|---|---|---|---|---|---|
| — | Control dampers (VCD / NRD / PRD)Models: SNRD, SPRD, SVCD, SVCD-HP, SVCD-MP, SVCD-Thttps://starduct.vn/en/san-pham/van-dieu-tiet/ | AMCA 500-D (test method) · SMACNA | Coated-steel frame and blades; V-profile blades with seals; round shaft, brass bearings | SVCD: VIBM test report (2017); SVCD-HP: leakage tested to AMCA 500-D in Starduct's in-house laboratory (914 × 914 specimen, in-house result); SVCD-MP, SVCD-T, SPRD, SNRD: calculated – not tested. | VIBM test report; in-house test results; catalogue, DoP, selector. |
| — | Fire dampersModels: S-FSD-L210-0175.24, S-FSD-L210-0723.23, S-FSS-L210, S-MFD-FS-L400, S-MFSD-M2/K, S-MFSD-S1/B, S-MFSD-L210, S-MFSD-L210-C, S-MFSD-L600, S-MFSD-L600-C, S-MFSD-L600-D, S-MFSD-MB, S-MFSD-WB, S-MFSD-WF, SAFD-H-L210, SAFD-L210https://starduct.vn/en/san-pham/van-ngan-chay/ | ISO 21925 · ISO 10294 · TCVN 9311 · QCVN 06:2023/BXD | Single / multi-blade; spring-return actuator or fusible link; insulation to the EI rating | EI rating per the fire test report of each model (report number on the model page); the L600 range holds fire-safety inspection certificates. Pressure drop and closed leakage by size are calculated, outside the scope of the fire test. | Fire test reports per model; fire-safety inspection certificates 4420, 897, 945/KĐ-PCCC-P7 (L600 range); DoP, catalogue, selector. |
| — | Tunnel dampersModels: STD-TDhttps://starduct.vn/en/san-pham/theo-yeu-cau/van-gio-duong-ham/ | Designed to UL 555S / AMCA 500-D / BS 476-20 (testing registration in progress) | Steel airfoil blades, reinforced steel frame; electric or pneumatic actuation | No published performance data; data for each configuration is provided with the quotation and identified as calculated. | Project-specific documents — contact sales. |
| — | Grilles, diffusers & louvresModels: DAG, SAD, SAG, SCLB, SCLB-LS, SECG, SFB, SPG, SRAG, SRRAG, SWL, SAC, SAL-F, SAL-V, SSL, WWL-E, WWL-K, WWL-V, FK025, FK026, FK028, FK037, FK041, FK043, FK048, SKD-K1, SKD-K2, SKD-K3, SKD-S, SRD-1, SRD-2, SRD-4, STD, STR-1R, STR-2R, STRD, SWF, SWS, SKD, SLD, SDV-W1, SDV-W3, SDV-K, SDV-HR, SDV-R, SDV-F, SDV-SR, SDV-T, SDV-TH, SDV-Dhttps://starduct.vn/en/san-pham/cua-gio/ | ASHRAE 70 · ADC 1062 GRD-84 · AMCA 500-L (louvres, calculation basis) | Extruded aluminium, powder coated; one-piece stamped diffuser faces | SAG, DAG, SKD, SLD: Intertek measurements to ASHRAE 70 on the tested specimens; other sizes and models: calculated – not tested (performance not yet published for some models). | Intertek reports 104519155CRT-001a…d; catalogue, DoP, selector. |
| — | Silencers & acoustic louvresModels: S-LSt-150T50, S-LSt-300T100, S-LSt-300T50, S-LVo-250, S-LVo-500, S-LVt-300T50, S-LVt-600T100, S-LVt-600T50, S-RC1, S-RCP, S-RDi, S-RDo, S-RDshttps://starduct.vn/en/san-pham/tieu-am/ | ISO 7235 · ISO 10140 · AMCA 500-L (calculation basis) | Perforated steel, mineral-wool absorber and fibre barrier; coated-steel casing | Insertion loss, self-generated noise and pressure drop: calculated – not tested. | Catalogue, DoP, selector (calculated values labelled). |
| — | VAV / CAV boxesModels: S-VAV-S, S-VAV-R, S-VAV-D, S-MV, S-VAV-SW / S-VAV-SE / S-VAV-SP, S-VAV-PF / S-VAV-PFW / S-VAV-PFE, S-VAV-LE, S-CAV-R, S-CAV-Qhttps://starduct.vn/en/san-pham/vav-box/ | AHRI 880 · AHRI 885 · ASHRAE 130 | Zn-Al-Mg coated-steel casing, closed-cell insulation, Belimo controller | S-VAV-S: AHRI Certified for 7 sizes 04, 05, 06, 08, 10, 12, 14 (AHRI Directory); catalogue data from Intertek measurements. Sizes 07, 09, 16 and the other models (S-VAV-R, S-VAV-D, S-MV, reheat, fan-powered, S-VAV-LE): calculated – not tested, no AHRI mark. | AHRI Ref 213355061–213355067; Intertek AHRI 880 / ASHRAE 130 reports; catalogue, DoP, selector. |
| — | Metal & fire-rated (EI) ductwork | SMACNA · TCVN 5687:2024 · ISO 6944-1 (EI duct) | Galvanised / Zn-Al-Mg steel by SMACNA pressure class; EI duct per the tested system | No data published on the website yet. | Project-specific documents — contact sales. |
| — | Flexible ducts & flexible connectorsModels: RO, SI, STF, STIhttps://starduct.vn/en/san-pham/ong-gio/ | Heat resistance tests (Quatest 1) · pressure drop calculated per the ASHRAE Handbook | Aluminium / polyester flexible duct with steel-wire helix, insulated type; technical-fabric flexible connectors | STF, STI: heat / cold resistance tests at Quatest 1; SI: heat resistance 300 °C / 120 min (specimen SI-45-100); pressure drop, heat transfer, acoustics: calculated – not tested; RO: no fire classification yet. | Quatest 1 test reports; DoP, catalogue, selector. |
| — | UNISTAR seismic bracing & hanger accessoriesModels: UTT071, UTT10, UTT11, UTT13, UTT18, UTT20, UTT20Q, UTTH10Qhttps://starduct.vn/en/san-pham/quang-treo-giang/ | FM 1950 · UL 203A · NFPA 13 | Structure attachments, pipe clamps, braces; coated steel | FM Approved (PR467307, FM 1950) for UTT10, UTT11, UTT13, UTT20. UL File EX29806 (UL 203A, category VGMY) — check current models on UL Product iQ. | FM Approvals PR467307; UL File EX29806; DoP, catalogue, selector. |
| — | Cable trays & laddersModels: RW, SC, SL, SThttps://starduct.vn/en/san-pham/thang-mang-cap/ | TCVN 10688:2015 / IEC 61537:2006 | Galvanised, Zn-Al-Mg, stainless or powder-coated steel; cold-formed, weld-free joints | Loads: measured per VIBM test reports where available, otherwise calculated. The TCVN 10688 / IEC 61537 certificate of conformity is being renewed — contact sales. | VIBM load test reports; DoP, catalogue, selector. |
| — | Energy recovery ventilators (ERV)Models: ERVhttps://starduct.vn/en/san-pham/theo-yeu-cau/erv/ | ASHRAE 62.1 · ASHRAE 90.1 · TCVN 5687:2024 | EC fans, sensible / total heat-exchanger core, filters, controller | No published performance data; design-specific data is provided with the quotation. | Project-specific documents — contact sales. |
3. Manufacturer capability
| Item | Details |
|---|---|
| ISO 9001:2015 | Quality management system, certificate VN-10161-QMS. |
| ISO 14001:2015 | Environmental management system, certificate VN-10038-EMS. |
| AHRI Directory | Single-duct VAV S-VAV-S, 7 sizes (AHRI Ref 213355061–213355067), renewed annually. |
| FM Approvals | PR467307 (FM 1950): seismic bracing UTT10, UTT11, UTT13, UTT20. |
| UL Solutions | File EX29806 (UL 203A, category VGMY): seismic bracing — check current models on UL Product iQ. |
| QUACERT | The cable-tray certificate of conformity (TCVN 10688 / IEC 61537) is being renewed — contact sales. |
| Fire-safety inspection | Fire-safety inspection certificates 4420, 897, 945/KĐ-PCCC-P7 for the L600 fire-damper range (S-MFSD-L600, -L600-D, -L600-C). |
| AMCA International | Member since 2020 (membership, not a product certification). |
| In-house laboratory | Pressure drop, airflow and leakage measured at the Dan Phuong factory; results identified as in-house. |
| Selection data | Catalogues, quick selectors and DoPs in 5 languages on the website; every value marked measured / certified / calculated. |
| BIM library | Revit families (.rfa) and IFC by product code. |
| Operation & maintenance | O&M manuals and training courses by product line. |
4. Basis of data
Measured: with laboratory and report number. Certified: with certificate number, valid only for the models / sizes named in the certificate. "Calculated – not tested": marked on the catalogue, the selector and the per-model submittal. Results from Starduct's in-house laboratory are identified as in-house.
The technical submittal per model (tag schedule, performance, drawings, DoP) is printed from each line's quick selector.