Starduct silencers & acoustic louvres

Silencer presentation: rectangular and circular duct silencers, acoustic louvres, materials, data basis, selection and installation.

Product pages

Use ← → to change slides, Esc to exit.

SILENCERS · ACOUSTIC LOUVRES

Starduct silencers & acoustic louvres

Rectangular and circular duct silencers and acoustic louvres — made at the Starduct factory, Hanoi.

Slide 1 / 13

Made in Vietnam · Supplied to 17 markets

HVAC & M.E.P equipment manufacturer · Vietnam

AMCA · AHRI · ASHRAE · VISRAEMember of international and Vietnamese HVAC engineering associations
UL · FM · Intertek · IBST · VIBMRegular testing and certification with independent laboratories
5 patentsGranted in Vietnam
In-house aerodynamic test labPressure drop, airflow and leakage measured at the factory

“Vietnamese engineering can do it — and do it better.”

Starduct silencers & acoustic louvresSlide 2 / 13

Slide 2 / 13
Selected by octave band

SILENCERS · ACOUSTIC LOUVRES

Selected by octave band

Attenuation and pressure drop are calculated for each size and length by octave band; the quick selector suggests the smallest size that meets the required attenuation.

13silencer and acoustic louvre models
5rectangular and circular duct silencers
8acoustic louvres with straight, oval and V blades

Starduct silencers & acoustic louvresSlide 3 / 13

Slide 3 / 13
Noise control along the duct and through the façade

OVERVIEW

Noise control along the duct and through the façade

01Duct silencersAfter supply and return fans, AHUs, large FCUs · Meeting rooms, hotels, hospitals, studios, theatres · Ducts passing from noisy to quiet zones (cross-talk control)
02Acoustic louvresFresh-air intakes and exhausts of plant rooms, chillers, generators · Screens around rooftop plant, substations, cooling towers · Where natural ventilation is needed but noise to neighbours must be limited
03One document setCatalogue in five languages, declaration of performance (DoP) and submittal printed from the selector — all from the same calculation engine.

Starduct silencers & acoustic louvresSlide 4 / 13

Slide 4 / 13
Slide 5 / 13
Splitters and lined casings

RECTANGULAR SILENCERS

Splitters and lined casings

01S-RDs — splitter silencerSplitters per standard layout table, W 450–2400 mm, open area 47–63 % · Strong attenuation at 500–2000 Hz
02S-RDi / S-RDo — linedFour-side lining, t = 50 / 100 / 150 mm · Casing size = duct size
03Pressure drop and self-noisePressure drop from airway velocity · Generated-noise data by velocity
04ConnectionsTDC, C or V30/40/50 flanges

Starduct silencers & acoustic louvresSlide 6 / 13

Slide 6 / 13
Slide 7 / 13
Duct silencer materials

MATERIALS

Duct silencer materials

01Outer casingGalvanised steel 1.2 mm, TDC or V flange
02Perforated facingGalvanised steel, Ø5 holes, 0.58 mm
03Acoustic infillMineral wool (rockwool) 80 kg/m³
04Anti-erosion facingBlack glass-fibre cloth 162 g/m²

Starduct silencers & acoustic louvresSlide 8 / 13

Slide 8 / 13
Slide 9 / 13
Acoustic louvre construction

ACOUSTIC LOUVRES

Acoustic louvre construction

01Blade skinSolid top skin (rain lip); perforated 0.58 mm bottom skin (drain lip)
02ModulesModule up to 1200 × 2500 mm, combined for larger openings
03Frame and finishGalvanised, powder-coated or ZAM frame
04OptionsStainless insect screen (option)

Starduct silencers & acoustic louvresSlide 10 / 13

Slide 10 / 13

DATA BASIS

Calculated – not tested

Duct silencersAttenuation and pressure drop are calculated with ISO 7235 as the basis; S-RDi and S-RDo are cross-calculated from S-RDs.
Acoustic louvresPressure drop and free area use AMCA 500-L, transmission loss uses ISO 10140-2 as the calculation basis; S-LVt pressure drop awaits testing.
On every documentCatalogue, selector and submittal carry the label “Calculated – not tested”; the declaration of performance (DoP) states NPD for performance characteristics.
When test reports arriveMeasured values replace calculated ones in the catalogue, selector and DoP at the same time, because all documents share one engine.

Starduct silencers & acoustic louvresSlide 11 / 13

Slide 11 / 13

SELECTION & INSTALLATION

Four steps from noise target to installation

01Enter conditionsAirflow, duct or wall-opening size, and the attenuation needed per octave band.
02Choose the sizeThe quick selector suggests size and length; compare attenuation, pressure drop, velocity and self-noise.
03SubmitAdd to the project list, print the submittal with the DoP; export CSV / JSON for the BOQ.
04InstallSilencers are heavy: support them independently, respect the airflow direction and avoid flanking. Louvres fit into prepared wall openings; frames are fixed to the structure for wind load.

Starduct silencers & acoustic louvresSlide 12 / 13

Slide 12 / 13

CONTACT

Select, submit and order

Size units in the quick selector, download catalogues and DoPs from the product pages, and send your list for a quotation.