Cable trays Derived from catalogue – not tested
SC
Perforated cable tray SC
Perforated-base tray for cable routes that need ventilation and easy cable fixing.
Technical description
| Model code | SC |
|---|---|
| Category | Cable trays |
| Production sizes | W 100–600 × H 50/75/100 mm |
| Order code | SC-300x100-GI |
Source: Derived from catalogue – not tested
Testing
| Test report | 3466/VLXD-TBMT |
|---|---|
| Laboratory | VIBM – Vietnam Institute for Building Materials (Ministry of Construction), Centre for Equipment, Environment & Occupational Safety (CEELS) |
| Date | 2023-08-21 |
| Standard | TCVN 10688:2015 (IEC 61537:2006) |
| Specimen | Perforated cable tray system, powder-coated steel + accessories 300W×100H×1.15T; SWL 510 N/m; specimen submitted by QUACERT (certification test) |
| Measured | SWL 51 kg/m @ L 1 m (300×100 t 1.15 P): deflection 1.18 / 1.24 mm (−5 / +60 °C); no damage at 57.8 kg · Impact 10 J at -5 °C: pass · Surface resistance: non-conductive (≥ 100 MΩ) · Electrical continuity of tray body: 0 mΩ/m (≤ 5 mΩ/m) · Neutral salt spray 96 h, NaCl 5 %, 35 °C (ISO 9227:2017): A = 0 % (rating 10 – ISO 10289) · Coating thickness 92.2 µm |
| Test report | 13738/VLXD-TBMT · 2019-12-16 — SWL 205.3 kg/m @ L 1.5 m (600×200 t 2.5 GI): deflection 3.53 / 3.94 mm (−5 / +60 °C); no damage at 524 kg · Impact 5 J at -5 °C: pass · Surface resistance: conductive (< 100 MΩ) · Glow-wire 650 °C/30 s (TCVN 9900-2-11 / IEC 60695-2-11): no ignition; flame 1 kW/60 s (TCVN 9900-11-2 / IEC 60695-11-2): no flame spread · Neutral salt spray 96 h, NaCl 5 %, 35 °C (ISO 9227:2017): 1 % < A ≤ 2.5 % (rating 5 – ISO 10289) |
| Test report | 13739/VLXD-TBMT · 2019-12-16 — SWL 205.3 kg/m @ L 1.5 m (600×200 t 2.5 P): deflection 3.69 / 4.19 mm (−5 / +60 °C); no damage at 524 kg · Impact 5 J at -5 °C: pass · Surface resistance: non-conductive (≥ 100 MΩ) · Glow-wire 650 °C/30 s (TCVN 9900-2-11 / IEC 60695-2-11): no ignition; flame 1 kW/60 s (TCVN 9900-11-2 / IEC 60695-11-2): no flame spread · Neutral salt spray 96 h, NaCl 5 %, 35 °C (ISO 9227:2017): 0 % < A ≤ 0.1 % (rating 9 – ISO 10289) |
| Test report | 13740/VLXD-TBMT · 2019-12-16 — SWL 205.3 kg/m @ L 1.5 m (600×200 t 2.5 S): deflection 3.04 / 3.48 mm (−5 / +60 °C); no damage at 524 kg · Impact 5 J at -5 °C: pass · Surface resistance: conductive (< 100 MΩ) · Glow-wire 650 °C/30 s (TCVN 9900-2-11 / IEC 60695-2-11): no ignition; flame 1 kW/60 s (TCVN 9900-11-2 / IEC 60695-11-2): no flame spread · Neutral salt spray 96 h, NaCl 5 %, 35 °C (ISO 9227:2017): 0 % < A ≤ 0.1 % (rating 9 – ISO 10289) |