Starduct EI fire dampers

Fire damper presentation: models, EI classes from fire test reports, PCCC inspection certificates, construction, installation and selection.

Product pages

Use ← → to change slides, Esc to exit.

EI FIRE DAMPERS

Starduct EI fire dampers

Insulated motorised fire dampers, fusible-link dampers and make-up air dampers — EI class from each model's fire test report; made at the Starduct factory, Hanoi.

Slide 1 / 13
Made in the Starduct factory, tested by independent laboratoriesMade in the Starduct factory, tested by independent laboratoriesMade in the Starduct factory, tested by independent laboratories

Made in Vietnam · Supplied to 17 markets

Made in the Starduct factory, tested by independent laboratories

AMCA · AHRI · ASHRAE · VISRAEMember of international and Vietnamese HVAC engineering associations
UL · FM · Intertek · IBST · VIBMRegular testing and certification with independent laboratories
5 patentsGranted in Vietnam
In-house aerodynamic test labPressure drop, airflow and leakage measured at the factory

“Vietnamese engineering can do it — and do it better.”

Starduct EI fire dampersSlide 2 / 13

Slide 2 / 13
EI class from each model's own fire test report

EI FIRE DAMPERS

EI class from each model's own fire test report

Insulated fire dampers with Belimo or KLB actuators, fusible-link dampers and make-up air dampers; fire tested at the University of Fire Prevention and Fighting and at IBST.

16fire damper and make-up air damper models
EI 180highest fire rating tested
15fire test reports to ISO 21925-1 / ISO 10294-1
3fire protection equipment inspection certificates

Starduct EI fire dampersSlide 3 / 13

Slide 3 / 13
Slide 4 / 13
Slide 5 / 13

FIRE TEST REPORTS

EI class — motorised dampers

ModelClassMeasuredTest reportLaboratoryDate
S-MFSD-S1/B EI 180 EI 183 min 0884-2026/TNCL-TT1 1 09/01/2026
S-MFSD-M2/K EI 180 EI 183 min 0933-2026/TNCL-TT1 1 06/03/2026
S-MFSD-L210 EI 120 EI 135 min 0204-2024/TNCL 1 15/04/2024
S-MFSD-L210-C EI 120 EI 136 min 0280-2024/TNCL 1 21/05/2024
S-MFSD-MB EI 120 EI 123 min 0838-2025/TNCL-TT1 1 12/12/2025
S-MFSD-WB EI 60 EI 68 min 0839-2025/TNCL-TT1 1 12/12/2025
S-MFSD-WF EI 60 EI 62 min 0723-2025/TNCL-TT1 1 13/10/2025
SAFD-L210 EI 30 EI 33 min 0127-2024/TNCL-TT2 1 24/10/2024
SAFD-H-L210 EI 60 EI 60 min 0230-2024/TNCL-TT2 1 23/12/2024

1 VLAT-2.0552 – Centre for Applied Research of Fire Science & Technology, University of Fire Prevention and Fighting

EI class and measured value from the test report; click a model code to open its page.

Starduct EI fire dampersSlide 6 / 13

Slide 6 / 13

FIRE TEST REPORTS

EI class — fusible-link dampers and the L600 range

ModelClassMeasuredTest reportLaboratoryDate
S-FSD-L210-0175.24 EI 120 EI 123 min 0175-2024/TNCL 1 27/03/2024
S-FSD-L210-0723.23 EI 120 EI 123 min 0723-2023/TNCL 1 17/10/2023
S-FSS-L210 EI 120 EI 136 min 0289-2024/TNCL 1 29/05/2024
S-MFSD-L600 EI 120 EI 120 min 064.22.KC.NCPCC 2 31/03/2022
S-MFSD-L600-D EI 120 EI 120 min 332.22.KC.NCPCC 2 07/10/2022
S-MFSD-L600-C EI 120 EI 123 min 066.22.KC.NCPCC 2 31/03/2022

1 VLAT-2.0552 – Centre for Applied Research of Fire Science & Technology, University of Fire Prevention and Fighting

2 Fire Safety Laboratory FSE (LAS-XD 416) – Vietnam Institute for Building Science and Technology (IBST)

S-FSD-L210-0175.24: EI 120 up to 2364 × 1764 mm; larger sizes: EI 90.

EI class and measured value from the test report; click a model code to open its page.

Starduct EI fire dampersSlide 7 / 13

Slide 7 / 13

PCCC INSPECTION

L600 range — IBST reports and PCCC inspection certificates

ISO 10294-1 · TCVN 9311-1Fire tested at the FSE fire laboratory, Vietnam Institute for Building Science and Technology (IBST); inspection certificates issued by the Police Department of Fire Prevention, Fighting and Rescue.
IBST test reports S-MFSD-L600 064.22.KC.NCPCC (2022)S-MFSD-L600-D 332.22.KC.NCPCC (2022)S-MFSD-L600-C 066.22.KC.NCPCC (2022)
PCCC inspection certificate 4420/KĐ-PCCC-P7 Fire protection equipment inspection · S-MFSD-L600 Issued 27/10/2022897/KĐ-PCCC-P7 Fire protection equipment inspection · S-MFSD-L600-D Issued 06/03/2023945/KĐ-PCCC-P7 Fire protection equipment inspection · S-MFSD-L600-C Issued 08/03/2023
ISO 9001 · ISO 14001ISO 9001:2015 (VN-10161-QMS) · ISO 14001:2015 (VN-10038-EMS).

Starduct EI fire dampersSlide 8 / 13

Slide 8 / 13
Insulated casing and blade — S-MFSD-L210 specimen

CONSTRUCTION

Insulated casing and blade — S-MFSD-L210 specimen

01Innermost layerMgSO₄ fire board 10 mm, 980 kg/m³
02Insulation layerMgO board 38 mm, 350–380 kg/m³
03Blade coreGalvanised steel 1.5 mm in the middle
04Blade insulationCeramic wool 2 × 20 mm, 220 kg/m³

Materials as listed in §3.1–3.2 of report 0204-2024/TNCL.

Starduct EI fire dampersSlide 9 / 13

Slide 9 / 13
Install as tested

S-MFSD-L600-D — test specimen as installed

INSTALLATION

Install as tested

01Install as the tested specimenThe damper only achieves its fire rating when installed as tested. Follow the installation instructions in the product file and the approved design.
02Handling and storageReceive and store in a dry place · Wear protective gloves · Do not step or climb on · Do not drop, roll, tip or drag
03Maintenance every 6 monthsCheck power supply, test closing/opening by actuator and by hand, clean blade and seals, record in the maintenance log. Provide an access door to reach the damper.

As in the S-MFSD-L210 catalogue; see the Installation section of each model's catalogue.

Starduct EI fire dampersSlide 10 / 13

Slide 10 / 13

DECLARATION SCOPE

Measured, calculated and in progress

EI classEI class is stated from the fire test report, with the report number; the declaration of performance (DoP) lists only measured and certified values.
Pressure drop and closed leakagePressure drop and leakage are calculated reference values for design and are outside the ISO 21925-1 fire certification scope. They will be replaced by measured data from extended testing when available.
Dampers larger than the specimenSplit into several dampers following each model's rule; the selector shows the number of dampers and each damper's size.
S-MFD-FS-L400 · EN 1366-2A 600 × 600 × 400 mm specimen with its actuator and enclosure was fire tested to EN 1366-2 and ISO 21925-1 at a laboratory in Guangzhou, China, achieving EI 180. Pressure drop and leakage were measured internally by Starduct on 180 × 180 and 600 × 600 samples.

Starduct EI fire dampersSlide 11 / 13

Slide 11 / 13

SELECTION

Four steps to select a fire damper

01EI class and actuationChoose the model by the EI class required for the fire wall or floor and by actuation: actuator or fusible link.
02SizeEnter the clear W × H; dampers larger than the specimen are split by the model's rule.
03Pressure drop, leakageChoose size and velocity to see airflow, pressure drop and closed leakage. Charts and lookup table update with your selection. Recommended velocity for ducts with fire dampers: 3–8 m/s.
04SubmitAdd to the project list, print the submittal with the issued DoP; export CSV / JSON for the BOQ.