EI fire dampers

← All groups

Fire dampers — FD / MFD types, installation, maintenance and warranty

Available

FD fusible-link / MFD actuator / SAFD make-up air mechanisms; identifying on site, construction groups, reading the order code, choosing the right type; transport, storage, pre-installation checks, installation as tested (MFD wiring, FD fuse, oversize dampers), acceptance, six-monthly maintenance; troubleshooting in elimination order; warranty conditions and claim file.

For
Distributors · MEP contractors · supervisors · warranty technicians
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • PowerPoint training slides with speaker notes — fire dampers HD-FD-2026.1 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
Fire dampers FD / MFD — types, installation, maintenance and warrantyThree closing mechanisms: FD fusible link / MFD actuator / SAFD make-up air; identifying on site and reading the order code; transport, storage, pre-installation checks; installing exactly as tested, dampers larger than the specimen; 6-monthly maintenance; troubleshooting in elimination order; warranty conditions. Based on guide HD-FD-2026.1.
Video language:
Wiring make-up air dampers — 2–10 V modulating and ON/OFF actuatorsTwo actuator types for make-up air dampers (modulating by blade angle and ON/OFF) and how to choose the lowest-cost code: SAFD-H-L210, SAFD-L210, S-MFSD-MB, S-MFSD-M2/K. Belimo BFN24-SR wire colours, single and parallel wiring, 24 V supply and voltage drop, fire alarm panel and three control options, wiring ON/OFF dampers at 24 V / 230 V, keeping power during a fire, commissioning. Based on guide HD-SAFD-ĐN-2026.1.
Take the test Multiple choice · auto-graded · certificate on pass

Control dampers

← All groups

Air dampers — telling VCD / NRD / PRD apart, installation, maintenance and warranty

Available

Principles and choosing the right volume control damper (VCD), non-return damper (NRD) or pressure relief damper (PRD); identifying on site, reading the ordering code; large dampers — sections, modules and actuators; transport, storage, pre-installation checks, installation by type, actuator wiring, balancing and acceptance; maintenance; troubleshooting in elimination order; warranty conditions and claim file.

For
Building operation teams · installation and commissioning technicians · distributors
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • PowerPoint training slides with speaker notes — air dampers HD-DMP-2026.1 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
Air dampers VCD / NRD / PRD — operation and maintenanceFor building operation teams: identifying dampers and their controls; start-up, balancing and locking the angle; pressure drop versus blade angle (CFD simulation, not tested) and operating notes; periodic maintenance and DW/144 checks; troubleshooting in elimination order; warranty. Based on guide HD-DMP-2026.1.
Take the test Multiple choice · auto-graded · certificate on pass

VAV boxes

← All groups

VAV boxes — operation & maintenance (common part)

Available

General description, safety and LOTO, pre-start checks, operation, controls and BMS points, monitoring, troubleshooting, maintenance, commissioning and acceptance, case exercises. Belimo ZoneEase controllers.

For
Building operation teams · installation and commissioning technicians · distributors
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • Starduct VAV box operation and maintenance (O&M) manual — common part S-VAV-S · S-VAV-R · S-MV, R6.5 — full edition with answer key (5 languages)
  • PowerPoint training slides with speaker notes — VAV R6.5 · H1.4 · F1.5 · D1.3 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
VAV box operation & maintenance — common partThe three lines S-VAV-S, S-VAV-R, S-MV; principle and pressure tubes; safety and 7-step energy isolation; correct / wrong installation on site; start-up and the rule never to change Vmin · Vmax · K; maintenance intervals; commissioning tests. Based on O&M manual R6.5.
Take the test Multiple choice · auto-graded · certificate on pass

Heated VAV boxes — supplement H

Available

Taken after the common part, for heated boxes: hot-water coil (SW), electric heater (SE, SP) and LE. Electrical and thermal safety, heater fire-safety logic, heating sequence, commissioning, maintenance.

For
Building operation teams · installation and commissioning technicians
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • Starduct VAV box O&M manual — supplement H: heated boxes S-VAV-SW · SE · SP · LE, H1.4 — full edition with answer key (5 languages)
  • PowerPoint training slides with speaker notes — VAV R6.5 · H1.4 · F1.5 · D1.3 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
VAV box operation & maintenance — supplement H (reheat)The four lines S-VAV-SW, SE, SP, LE; the two layers of heater protection (no airflow no heat, overheat cut-out), TC1 / TC2; isolating two supplies; heating sequence; 8 commissioning checks; maintenance and troubleshooting. Based on O&M manual H1.4.
Take the test Multiple choice · auto-graded · certificate on pass

Fan-powered VAV boxes — supplement F

Available

Taken after the common part, for fan-powered boxes S-VAV-PF / PFW / PFE: fan on/off and speed setting on the HS500W, filter, back-draft damper, PFE heater fire-safety logic, commissioning, maintenance.

For
Building operation teams · installation and commissioning technicians
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • Starduct VAV box O&M manual — supplement F: fan-powered boxes S-VAV-PF · PFW · PFE, F1.5 — full edition with answer key (5 languages)
  • PowerPoint training slides with speaker notes — VAV R6.5 · H1.4 · F1.5 · D1.3 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
VAV box operation & maintenance — supplement F (parallel fan)The three configurations S-VAV-PF, PFW, PFE; the fan only runs for heating; Belimo only switches it on / off, speed is set on the HS500W (6-step knob + 0–10 V potentiometer); MotorStop does not stop the fan; correct / wrong installation on site; 8 commissioning checks; filter and backdraft damper. Based on O&M manual F1.5.
Take the test Multiple choice · auto-graded · certificate on pass

Dual-duct VAV box — supplement D

Available

Taken after the common part, for the dual-duct box S-VAV-D: primary controller on the cold valve and secondary controller on the hot valve linked by MP-Bus, installation, BMS points, commissioning, maintenance.

For
Building operation teams · installation and commissioning technicians
Applies to
S-VAV-D
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • Starduct VAV box O&M manual — supplement D: dual-duct box S-VAV-D, D1.3 — full edition with answer key (5 languages)
  • PowerPoint training slides with speaker notes — VAV R6.5 · H1.4 · F1.5 · D1.3 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
VAV box operation & maintenance — supplement D (dual duct)The S-VAV-D dual duct box: cold and warm dampers into one mixing box; one main controller on the cold damper and a D3-MP-A7 secondary over MP-Bus (address 7); ducts to the labelled inlets, straight duct ≥ 1200 mm after the box; secondary BMS points; 8 commissioning checks; common faults. Based on O&M manual D1.3.
Take the test Multiple choice · auto-graded · certificate on pass

Air outlets

← All groups

Air outlets — types, installation, maintenance and warranty

Available

Four groups — blade grilles, ceiling diffusers, slot and jet outlets, louvers; identifying on site, reading the ordering code; transport, storage, pre-installation checks, installation (Frameless, louvers, modules), acceptance, maintenance; troubleshooting in elimination order; 10-year colour-warranty conditions and claim file.

For
Building operation teams · installation and commissioning technicians · distributors
Format
At your site · At the Starduct factory (with a factory audit) · Online

Free downloads

For distributors & instructors

PowerPoint slides with speaker notes and the answer key — download in the distributor portal (sign-in required).

  • PowerPoint training slides with speaker notes — air outlets HD-OUTLET-2026.1 (5 languages)
Sign in to the distributor portal ↗

Self-study videos

Video language:
Air outlets, ceiling diffusers and louvers — operation and maintenanceFor building operation teams: the four outlet groups and code suffixes (-O return, +OBD supply, -M, -FL); commissioning, balancing and setting OBD dampers; throw direction; condensation, weather louvers, fresh-air loss; 3/6/12-month maintenance, dirty filters causing low capacity and condensation, safe and tidy removal and refitting; troubleshooting in elimination order; 10-year colour warranty. Based on guide HD-OUTLET-2026.1.
Take the test Multiple choice · auto-graded · certificate on pass

Silencers & acoustic louvres

← All groups

Acoustic Basic — acoustics for HVAC/MEP engineers: silencers, vibration, resonance and a generator-room case study

Available

Five self-study lessons: decibels, octave bands, noise criteria and the source-to-receiver chain; silencer types and selection; silencer manufacturing and materials (thick splitters, thin panels, micro-perforated, high-temperature, fire-rated); transmission through the envelope, structure-borne vibration and resonance; a real case of a three-generator room on level 2 — silencers built differently from the design, recalculating the A–E chain, CFD airflow, heat and installation. Case-study figures are calculated, not yet tested.

For
HVAC/MEP design engineers · design consultants · mechanical contractors · distributors
Format
Online · At your site · At the Starduct factory (with a factory audit)

Self-study videos

Video language:
Lesson 1 · Acoustic basics for HVAC engineers · 7:33Sound, wavelength and the eight octave bands; adding decibels; sound power and sound pressure; indoor and outdoor noise criteria; the source-to-receiver chain with an exhaust fan example; six common mistakes in design documents.
Video language:
Lesson 2 · Silencer types and selection · 6:37The three inputs you need before selecting; the four numbers that compare silencers (insertion loss by band, pressure drop, self-noise, size); six silencer families in HVAC; sizing and length for the target, with a 20,000 m³/h exhaust fan example.
Video language:
Lesson 3 · Silencer manufacturing and materials · 11:47Silencer construction and the physics of absorption; thick splitters and what works at 63–250 Hz; thin panels and membrane absorbers; micro-perforated designs for clean and wet areas; materials, facings and casings; high-temperature and fire-rated silencers; production, aerodynamic noses and quality checks; acoustic louvres; writing the specification.
Video language:
Lesson 4 · Envelope, structure-borne vibration and resonance · 9:39Transmission through the envelope and flanking paths (ISO 12354), the mass law; structure-borne vibration: forcing frequencies, resonance, transmissibility, choosing isolator deflection; canvas flexible connectors, vibration bridges, start-up; structural resonance and room modes; GenRoom calculation tools.
Video language:
Lesson 5 · Case study: when the silencer is built differently · 10:30A three-generator room on level 2 of a grade A office tower: silencers designed with 200 mm splitters were built with 100 mm. GenRoom recalculates the A–E chain from source to the 1 m point, selects an L500 acoustic louvre, and checks CFD airflow, radiator fan pressure, heat, blade-by-blade installation on rails and the rail structure. Project anonymized; figures are calculated, not yet tested.

Register for training

Starduct sales will contact you to agree the date, venue and number of trainees.

Your details are used only to arrange the training — see the privacy policy.